Specifications
- System Components
- Mist Nozzles: Specialized nozzles designed to create ultra-fine water droplets with a size range of 10-50 microns.
- High-Pressure Pump: Pumps water at high pressures (typically 100-200 bar) to create fine mist.
- Water Supply: Connected to a water source, such as a municipal supply or dedicated storage tank, with adequate flow rate.
- Control Panel: Manages system operation, activating the suppression system based on fire detection signals.
- Fire Detectors: Can include smoke detectors, heat detectors, or flame detectors for early fire detection.
- Water Flow Rate
- Low Water Consumption: Dry mist systems use significantly less water than traditional sprinklers, typically consuming around 1-3 gallons per minute per nozzle.
- Efficient Fire Suppression: Uses fine droplets that absorb heat and reduce oxygen levels effectively without causing water damage to sensitive equipment.
- Activation Mechanism
- Automatic Activation: Triggered by fire detection systems (smoke, heat, or flame detection) via a control panel.
- Manual Override: Option for manual activation in emergency situations.
- Quick Response Time: System activates instantly upon detection of fire to minimize damage and extinguish flames quickly.
- Design and Coverage
- Flexible Coverage Area: Designed to protect a range of environments, from small server rooms to large industrial spaces.
- Nozzle Spacing: Nozzles are spaced at strategic intervals based on the room layout and fire hazard level to ensure full coverage.
- Compact Design: The system is discreet and can be integrated into existing infrastructure without bulky pipes or visible equipment.
- Pressure Rating
- Operates at high pressures (typically 100-200 bar) to atomize water into fine mist particles.
- Designed to withstand high-pressure environments without compromising system integrity.
- Environmentally Friendly
- Low Water Usage: Uses minimal water compared to traditional systems, reducing the environmental impact.
- No Harmful Chemicals: The system uses water vapor, making it non-toxic and safe for both humans and the environment.
- Safety & Efficiency
- Fast and Effective Suppression: Reduces flame temperature and oxygen levels quickly, preventing fire spread.
- Minimal Water Damage: Dry mist suppresses the fire effectively without causing the extensive water damage typical of traditional sprinkler systems.
- No Wet Surfaces: Unlike sprinklers, there is no soaking of the surrounding area, reducing cleanup and downtime.
- Applications
- Data Centers and Server Rooms: Protects sensitive electronic equipment from fire damage while preventing water-related issues.
- Industrial Facilities: Used in factories, chemical plants, and warehouses for fire suppression without causing water damage to goods or machinery.
- Museums and Libraries: Ideal for protecting valuable collections, archives, and artifacts from fire without the risk of water damage.
- Tunnels and Subways: Provides fire protection in confined spaces with limited access to traditional fire suppression systems.
- System Maintenance
- Regular Inspections: Monthly system checks to ensure proper functioning of the control panel, nozzles, and water supply.
- Annual Testing: Full system testing, including nozzle spray pattern and pressure checks, to confirm readiness.
- Compliance and Standards
- Compliant with NFPA 2001 and FM 5560 standards for fire suppression systems.
- Meets ISO 9001 certification for manufacturing quality.
- Designed for use in environments that require sensitive fire protection solutions.